Products

Fire Damper

A device used to restrict the passage of flame through the ductwork of an air system. A fire damper installed in a fire-rated wall or floor and closes automatically to maintain the integrity of that partition

Features:

  • DUCT TECH range of fire damper is available in Mechanical as well as motorized operation.

  • Duct Tech Complies with UL555 and UL555S standard.

  • Fire Damper are available in Galvanized steel as well as stainless steel construction.

  • Installation available in Vertical as well as horizontal wall, slab with concrete or Gypsum partition.

  • Frame thickness available in the range of 22 gauge ( 0.80MM) up to 16 gauge (1.60MM).

  • Blade thicknesses available in the range of 24 gauge up to 16 gauges.

  • Approved with Dubai, Abu Dhabi, Qatar and Oman Civil defense Authority.

image
image
image

DT-FD-90

Complies with UL555 and UL555S standard for 90 Min (1 ½ Hrs ) fire Rating fire damper which can be use up to 120Min ( 3Hr) rating fire partition

Duct Tech Fire damper complies for static and dynamic system.

Frame is made out of Galvanized Steel or Stainless Steel with thickness ranges from 0.80MM to 1.60MM.

Blade is made out of galvanized steel or stainless steel with thickness ranging from 0.70MM to 1.60MM.

Spring: Two stainless steel coil spring.

Ramp: Spring holder is manufactured from galvanized steel of stainless steel.

Installation : Vertical or Horizontal.

Option available with 12”, 14” or 16” sleeve or Installation frame.

image

DT-FDSL-90

Complies with UL555 and UL555S standard for 90 Min (1 ½ Hrs ) fire Rating fire damper which can be use up to 120Min ( 3Hr) rating fire partition

Duct Tech Fire damper complies for static and dynamic system.

Frame is made out of Galvanized Steel or Stainless Steel with thickness ranges from 0.80MM to 1.60MM.

Blade is made out of galvanized steel or stainless steel with thickness ranging from 0.70MM to 1.60MM.

Fusible Link : UL listed fusible link 165 F or 212 F or 312 F

Spring:Two stainless steel coil spring.

Ramp: Spring holder is manufactured from galvanized steel of stainless steel.

Installation : Vertical or Horizontal.

Option available with 12”, 14” or 16” sleeve or Installation frame.

image

DT-FD-120

Complies with UL555 and UL555S standard for 120 Min (3 Hrs ) fire Rating fire damper which can be use for more than 120Min ( 3Hr) rating fire partition.

Complies with NFPA 90A.

Duct Tech Fire damper complies for static and dynamic system.

Frame is made out of Galvanized Steel or Stainless Steel with thickness ranges from 0.80MM to 1.60MM.

Blade is made out of galvanized steel or stainless steel with thickness ranging from 0.70MM to 1.60MM.

Fusible Link : UL listed fusible link 165 F or 212 F or 312 F

Spring:Two stainless steel coil spring.

Ramp: Spring holder is manufactured from galvanized steel of stainless steel.

Installation : Vertical or Horizontal.

Option available with 12”, 14” or 16” sleeve or Installation frame.

image

DT-FD-SL-120

Complies with UL555 and UL555S standard for 120 Min (3 Hrs ) fire Rating fire damper which can be use for more than 120Min ( 3Hr) rating fire partition.

Complies with NFPA 90A.

Duct Tech Fire damper complies for static and dynamic system.

Frame is made out of Galvanized Steel or Stainless Steel with thickness ranges from 0.80MM to 1.60MM.

Blade is made out of galvanized steel or stainless steel with thickness ranging from 0.70MM to 1.60MM.

Fusible Link : UL listed fusible link 165 F or 212 F or 312 F

Spring:Two stainless steel coil spring.

Ramp: Spring holder is manufactured from galvanized steel of stainless steel.

Installation : Vertical or Horizontal.

Option available with 12”, 14” or 16” sleeve or Installation frame.

Fire Damepr Installation:

  • Fire Damper to be installed in plain wall or gypsum partition or Horizonal slab.

  • Breakaway joint to be installed with the sleeev and the ductwork.

  • Expansion clearance between the fire damper sleeve and the wall opening must be ¼” inch larger than the damper size for the damper size up to 24 inch and additional 1/8” per linear foot increase in the damper size.

  • Damper to Duct Connection: Damper has to be connected to duct as per the fig : 3.

  • Retaining angle to be provided on both side of damper , 18 gauge galvanized steel angle 1” width and 1” height.


  • image

    image
image
image
Contact us

Ready To Get Stared

"Stay cool and contact Duct Tech Airconditioning today for expert service and installation!"

Get Started